PPX18 260807
New features, patches, removals, and the exact PPX18 files updated in this version.
Previous releaseWhat you need to update: Pro Plan Project, Library — BWP users only. What changed: Plan Template, Layout Files, Library, User Manual, General.
What to install for PPX18 260807
Most users only need to replace the Pro Plan project file. Install the updated Pro Plan project package using the normal instructions in How to Update PPX18.
Install the Library update only if you use the Braced Wall Panel (BWP) tools. The Library update adds the BWP connection notes to the Pro Plan Tools Library. Users who do not use the BWP tools do not need to replace the Library for this release.
The updated project package includes the dedicated Detailed Designations plan and the updated Layout references required by the new performance-optimized workflow.
01New Features6 items
- Split the Detailed Designations system into its own dedicated plan file. The Detailed Designations link on the main Pro Plan page still works, but now opens the dedicated plan.
- Updated all Pro Plan Layouts so their detail pages reference the dedicated Detailed Designations plan.
- Added sill-cap and protective-coating options to Detail Designations and added those options to the new rigid-insulation details.
- Applicable Codes now follow Project Information automatically, including the selected code-cycle year. Users can edit the IRC code criteria for their region without switching the output to a manual override.
- Added breadcrumb notes to all Layout macros so users and future editors can more easily understand what each macro controls.
- Added a new Title Block Plan chapter section to the User Manual explaining the easiest method for exchanging specification writing.
02Performance Improvements4 items
- Rewrote the CSV system so it loads once during the Chief Architect session instead of reading the CSV file every time an object is drawn. After editing the CSV file, restart Chief Architect to load the changes.
- Moved the extensive Detailed Designations system out of the main Pro Plan. Chief Architect was continually parsing every Note in that system while drafting, adding approximately 100–400 milliseconds of lag per wall during testing, particularly through roughly the first 15 walls.
- The revised Pro Plan now performs very close to Chief Architect's default Residential Template in testing with Automatic Roofs and Automatic Foundations enabled.
- Removed the BWP connection notes from the plan CAD detail and moved them to the Pro Plan Tools Library so they are not continually parsed in the main plan.
03Patches and Improvements5 items
- Updated the CSV parser for macOS so paths using the tilde home-folder shortcut expand and parse correctly.
- Corrected several detail errors.
- Added BWP connection notes to the Pro Plan Tools Library for the Braced Wall Panel connection-note system.
- Added new Detailed Designations chapters to the PPX18 User Manual.
- Issued the 260807 check set. Only the Pro Plan template/project package has changed since 260803, except for the optional BWP Library content.
04Removed or Replaced3 items
- Replaced the Detailed Designations system stored inside the main Pro Plan with a dedicated Detailed Designations plan.
- Removed the BWP connection notes from the plan CAD detail after adding them to the Pro Plan Tools Library.
- Removed the need to switch Applicable Codes output to a manual override; regional IRC criteria and the code-cycle year are now controlled through Project Information.
05Known Issue3 items
- A Project Information input glitch has been observed. The exact cause has not yet been identified; a Chief Architect case will be reported and the changelog will be updated when more information is available.
- Until the dedicated Detailed Designations workflow has received broader testing, check the detail designations before printing.
- When placing a Detailed Designation from the Library, open either the Detailed Designations plan or the Layout once during each Chief Architect session. After either file has been opened, the Library designation tools should work normally for the remainder of that session.

