CHAPTER 24

Braced Wall Panel System

Placing, designating, displaying, and scheduling PPX18 braced wall panels

What the Braced Wall Panel tool does

The PPX18 Braced Wall Panel tool creates the panel graphic and reports the panel to the Braced Wall Panel schedule. The width of the placed tool establishes the reported panel width. From that width, the system automatically reports the applicable end-panel connections and braced-wall-panel specifications in the schedule. Always verify the reported requirements against the current adopted code and the conditions of the project.

Place the panel in a wall

The tool is built from a cabinet. Chief Architect cabinets can initially be placed against a wall when Bumping is enabled. Place the Braced Wall Panel cabinet against the wall first so it is created and begins reporting to the schedule. While it is selected, use the Point-to-Point Move tools to move it into the wall at the required location. Adjust its width to match the actual braced wall panel; the schedule and connection information respond to that width.

Braced wall panel cabinet positioned within a wall in plan view
Place the cabinet against the wall, then use Point-to-Point Move to position the panel within the wall Click to enlarge
Braced Wall Panel schedule reporting panel width and connection requirements
The panel width drives the reported connection and specification information in the Braced Wall Panel schedule Click to enlarge

Choose the braced wall panel type

The active braced wall panel type is selected on the Detail Designations CAD Detail. This designation affects more than the cabinet tool, so it is managed with the other coordinated detail designations. Choose the required braced wall panel type there and confirm that the plan label, panel schedule, nailing options, and connected notes report the intended method.

Braced Wall Nailing Options schedule
The coordinated nailing-options schedule reports fastening choices for the selected panel method Click to enlarge

BWP method codes

Use the BWP tool from the PPX18 library. The BWP package contains coordinated macros that generate the panel requirements for the selected bracing method, including minimum panel length, plate anchors, intermediate and top-plate connections, edge nailing, and additional requirements.

The supported method codes are: cs-wsp - continuous sheathing with wood structural panels; cs-gyp - continuous sheathing with gypsum board; cs-sfb - continuous sheathing with SFB; cs-ps - continuous sheathing with portal frame; ps1 - portal frame with one hold-down; ps2 - portal frame with two hold-downs; bwp - braced wall panel; gb - gypsum board; sfb - SFB; wsp - wood structural panel; pfh - portal frame with hold-downs; pfg - portal frame with gypsum; pfs - portal frame with SFB; and pfw - portal frame with wood structural panel.

Set a panel method directly

When a panel requires a method different from the coordinated Detail Designations selection, open the BWP cabinet and enter one of the supported codes in its Supplier field. Preserve the code spelling and hyphens exactly. That object will then use the selected method when the BWP macros generate its schedule values.

Values generated by the macros

bwp_min_panel_length returns the minimum panel-length requirement. bwp_plate_anchor returns the plate-anchor specification. bwp_intermediate_connection returns the intermediate connection requirements. bwp_top_plate_connection returns the top-plate connection requirements. bwp_additional_notes returns additional notes or requirements. bwp_edge_nailing returns the edge-nailing pattern.

Fallback values

If the Supplier field contains an unsupported method, the macros fall back to: a 48-inch minimum panel length; 1/2-inch x 8-inch anchor bolts at 6 feet on center; 16d intermediate connections at 6 inches on center at edges and 12 inches on center in the field; an H1 clip at each truss for the top-plate connection; 7/16-inch OSB sheathing; and 8d edge nailing at 6 inches on center at edges and 12 inches on center in the field.

Method-specific considerations

SFB methods may require manufacturer-specific requirements. Portal-frame methods may require additional hold-down specifications. Gypsum-board methods use nailing patterns that differ from wood structural panel methods. These macro outputs are a coordinated documentation aid, not a substitute for project-specific engineering or code review.

Verify every result

Rabbitt Design assumes no liability for the accuracy of these macro calculations or for consequences arising from their use. Users are responsible for verifying the selected method, every reported connection and specification, the applicable code requirements, the project conditions, and that the macros function as intended before issuing the documents.

Use the common braced wall panel notes

The Braced Wall Panel CAD Detail contains a custom schedule of common braced-wall-panel notes. To place a required note in the plan, cut it from that CAD Detail and paste it into the appropriate plan view. Confirm that every pasted note applies to the selected panel method and project conditions.

Show the panel in elevation or section

The tool is a blank cabinet box with a cabinet door style fashioned as a cross so the panel can be shown in elevation and section views. PPX18 wall types use separate display layers for their individual wall layers. Open the cross-section view and select a cross-section layer set whose name includes BWP. That layer set hides the outermost wall layer so the crossed cabinet-door graphic is revealed within the wall assembly.

Braced wall panel cross graphic visible in an elevation view
A cross-section layer set containing BWP reveals the crossed cabinet-door graphic inside the wall assembly Click to enlarge

Future braced wall line system

A future PPX18 development is planned for bracing systems that cannot be treated as continuous and must instead be calculated from a defined braced wall line and its related criteria. That planned braced-wall-line workflow is separate from the current panel tool described here.

Open the Detail Designations chapter
ESSENTIALS PLANNot included

Not included: the Braced Wall Panel system is removed from Essentials.

Essentials package: a stripped-down working plan, companion As-Built file, Title Block and Spec Plan, plus Rexel ANSI B (11 × 17) and Rexel ARCH D layouts. It includes no PPX18 toolbars or library items.